Week 33 - Parallel MD
From this week onwards an LHC ion cycle will be required in the PS for the PS start-up with Early LHC beam
Monday 13/08 (08:00 - 18:00) - PS-SPS transfer optimization (capture / flat-bottom losses)
Beam conditions: SPS user = LHC25 - PS users = LHC25A&B
#injections = 1(72 bunches) - Extraction from the PS w/o QKE58
Nb = 1.3 x 1011 p/b
Transverse emittances (e* < 3 mm)
Longitudinal emittance: eL* = 0.35 eV.s
Contact person: E. Shaposhnikova
Tuesday 14/08 (08:00 - 18:00) - Measurement of the SPS longitudinal impedance
Beam conditions: SPS user = MD1 - PS users = MD4
#bunches = 1
Nb = 1.3 x 1011 p/b (i.e. nominal intensity, possibility to decrease it)
Transverse emittances: e* ~ 1 mm
Longitudinal emittance: eL* ~ 0.2 eV.s - to be specified - no bunch rotation.
Contact person: E. Shaposhnikova
Wednesday 15/08 - Friday 17/08 (08:00 - 18:00) - Setting-up of an LHC pilot cycle in parallel to physics
Beam conditions: SPS user = MD1, PS users LHCPILOT, TSTLHC
Contact person: K. Cornelis
Author: Elias Métral - AB/ABP
Last update:
Tuesday, August 07, 2007 01:48:24 PM
Copyright
CERN