Week 32 - SPS Dedicated MD

Wednesday 08/08 (08:00 - 15:00) - Setting-up of the LHC  beam in the SPS (both transverse and longitudinal)

Change of supercycle => User: LHC25NS

During (the scrubbing run and) the LONG MDs with LHC beam the ZS are RETRACTED / HV to 0 kV / ION TRAPS ON (inform the ZS expert). The cooling circuit for the septa magnets (circuits 214, 414 and 614) should be switched OFF (by TI). Block the fast vacuum valves OUT in the injection and extraction areas (LSS1,LSS2,LSS6

Beam conditions: LHC25NS ( RF MMI pointing to LHC25 - PS USER=LHC25NS) in SPS on Cycle LHCMD25.92-55-270_PDOT_V2 (31.2 s long)

#injections = 1  (12 bunches) - Extraction from the PS w/o QKE58

Nb = 1.3 x 1011 p/b

Transverse emittances (e* < 3 mm)

Longitudinal emittance: eL* = 0.35 eV.s

Participants: OP, RF, ABP, BI

 

Wednesday 08/08 (15:00 - 16:00) - Setting-up of the feedback, feed-forward and longitudinal feedback

Beam conditions: LHC25NS ( RF MMI pointing to LHC25 - PS USER=LHC25NS) in SPS on Cycle LHCMD25.92-55-270_PDOT_V2 (31.2 s long)

#injections = 1-2  (72 bunches) - Extraction from the PS w/o QKE58

Nb = 1.3 x 1011 p/b

Transverse emittances (e* < 3 mm)

Longitudinal emittance: eL* = 0.35 eV.s

Participants: T. Bohl, RF

 

Wednesday 08/08 (16:00 - 20:00) - Coast setting-up at 270 GeV/c

Beam conditions: LHC25NS ( RF MMI pointing to LHC25 - PS USER=LHC25NS) in SPS on Cycle LHCMD25.92-55-270_PDOT_V2 (31.2 s long)

#injections = 1  (12 bunches) - Extraction from the PS w/o QKE58

Nb = 1.3 x 1011 p/b

Transverse emittances (e* < 3 mm)

Longitudinal emittance: eL* = 0.35 eV.s

Participants: OP, RF, BI

In the last hour possibility to take some parasitic measurements for SPS in double harmonic RF system

 

Wednesday 08/08 (20:00) - Thursday 09/08 (04:00) - Study of beam stability at low energy and V-ECI dependence on energy

Beam conditions: LHC25NS ( RF MMI pointing to LHC25 - PS USER=LHC25NS) in SPS on Cycle LHCMD25.92-55-270_PDOT_V2 (31.2 s long)

#injections = 1-4  (72 bunches) - Extraction from the PS w/o QKE58

Nb = 1.3 x 1011 p/b

Transverse emittances (e* < 3 mm)

Longitudinal emittance: eL* = 0.35 eV.s

Participants: G. Arduini, T. Bohl, R. Calaga, G. Papotti, G. Rumolo, E. Shaposhnikova, F. Zimmermann, OP

 

Thursday 09/08 (04:00 - 08:00) - Abort gap cleaning tests in the SPS in view of LHC

Beam conditions: LHC25NS ( RF MMI pointing to LHC25 - PS USER=LHC25NS) in SPS on Cycle LHCMD25.92-55-270_PDOT_V2 (31.2 s long)

#injections = 1  (<72 bunches - gaps of multiples of 12 bunches in the standard batch are required) - Extraction from the PS w/o QKE58

Nb = 0.3-0.5 x 1011 p/b

Transverse emittances (e* < 3 mm)

Longitudinal emittance: eL* = 0.35 eV.s

Contact person: W. Höfle, A. Koschik

 


Author: Elias Métral - AB/ABP
Last update: Monday, August 06, 2007 07:12:12 PM
Copyright CERN